Basic product info
product name:
0.6/1kV PVC Insulated Aerial Bundle Cable
(Aerial Bundled Conductor, Service Drop Cable
ABC cable 1C25 sqmm
ABC cable 3C25 sqmm
ABC cable 3C25 sqmm +1C16 sqmm
product properties
Brand: Yiteng
Model: ABC cable
Certification: CCC ISO9001 ISO14001
Trading Information
Minimum order quantity: 10000 meters
Price: FOB tianjin USD 0.1-50 per meter
Payment method: T/T L/C at sight DA DP Western Union
Supply Ability: 10000 meters per week
Delivery date: 15-20 days after payment
Conventional packaging: Wooden drum Or as per reqyuirement
product description
0.6/1kV PVC Insulated Aerial Bundle Cable
(Aerial Bundled Conductor, Service Drop Cable)
Description
For single core PVC insulated or covered aerial cable without messenger or neutral conductor, the phase conductor may be AAC or AAAC or ACSR or Copper.
For more than one core PVC insulated aerial cable with or without messenger or neutral conductor and with or without street lighting conductor, the phase conductor and street lighting conductor are AAC with PVC insulation, and the messenger or neutral conductor is AAAC or ACSR with or without PVC insulation.
Operating Characteristics
Rated voltage: 0.6/1kV
Max. permissible continuous operating temperature of conductor with PVC insulation: 70°C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 160°C
The ambient temperature under installation should not be lower than: -20°C
The bending radius of cable is recommended as following:
When the diameter of cable is less than 25mm: not less than 4 times of the diameter of cable
When the diameter of cable is not less than 25mm: not less than 6 times of the diameter of cable
When the cable is used in alternative current system, the rated voltage of cable should be at least equal to the rated voltage of system; when the cable is used in direct current system, the rated voltage of system should not greater than 1.5 times of the rated voltage of the cable.
Application
PVC insulated aerial cable as a new-type aerial cable is used for overhead electric power transmission, extensively used in rebuilding of urban and forest region electrified wire netting. It improves the safety and reliance of electrified wire netting.
Manufacturing Standards GB/T 12527-2008, IEC 60502-1, BS 7870-5
ABC Cables without Street Lighting | |||||||
1+1 Structure | |||||||
Phase Conductor | Neutral Conductor | Completed Cable | |||||
Section | Insulation Thickness | Electrical Resistance | Section | Insulation Thickness | Electrical Resistance | Overall Diameter | Cable Weight |
DC.20°C | DC.20°C | ||||||
No.xmm2 | mm | Ω/km | mm2 | mm | Ω/km | mm | kg/km |
1×25 | 1.3 | 1.20 | 25 | 1.3 | 1.20 | 17.6 | 210 |
1×35 | 1.3 | 0.868 | 35 | 1.3 | 0.868 | 19.6 | 270 |
1×50 | 1.5 | 0.641 | 50 | 1.5 | 0.641 | 23 | 360 |
1×70 | 1.5 | 0.443 | 70 | 1.5 | 0.443 | 26.4 | 500 |
1×95 | 1.7 | 0.320 | 95 | 1.7 | 0.320 | 30.6 | 680 |
3+1 Structure | |||||||
Phase Conductor | Neutral Conductor | Completed Cable | |||||
Section | Insulation Thickness | Electrical Resistance | Section
|
Insulation Thickness | Electrical Resistance | Overall Diameter | Cable Weight |
DC.20°C | DC.20°C | ||||||
No.xmm2 | mm | Ω/km | mm2 | mm | Ω/km | mm | kg/km |
3×25 | 1.3 | 1.20 | 25 | 1.3 | 1.20 | 21.2 | 410 |
3×35 | 1.3 | 0.868 | 35 | 1.3 | 0.868 | 23.7 | 550 |
3×50 | 1.5 | 0.641 | 50 | 1.5 | 0.641 | 27.8 | 730 |
3×70 | 1.5 | 0.443 | 70 | 1.5 | 0.443 | 31.9 | 1000 |
3×95 | 1.7 | 0.320 | 95 | 1.7 | 0.320 | 36.9 | 1370 |
3×120 | 1.7 | 0.253 | 120 | 1.7 | 0.253 | 40.6 | 1690 |
ABC Cables with Street Lighting | |||||||
3+1+1 Structure | |||||||
Phase Conductor | Neutral Conductor | Street Lighting Conductor | Completed Cable | ||||
Section | Insulation Thickness | Section | Insulation Thickness | Section | Insulation Thickness | Overall Diameter | Cable Weight |
No.xmm2 | mm | mm2 | mm | mm2 | mm | mm | kg/km |
3×50 | 1.5 | 50 | 1.5 | 25 | 1.3 | 29.8 | 830 |
3×70 | 1.5 | 70 | 1.5 | 25 | 1.3 | 33.6 | 1100 |
3×95 | 1.7 | 95 | 1.7 | 25 | 1.3 | 38.2 | 1470 |